| Standard specification |
| Model No. | HAL960 | |
| Number of channels | 1CH | |
| Frequency | 12‚‹Hz | |
| Object to be measured | Liquid/Powder | |
| Measurement distance range (1/2 for powder) |
1.5 to 60m | |
| Measurement | 5mm | |
| Display | 5mm | |
| Accuracy | }0.25%F.S. (}15cm) | |
| Data update cycle | 1.5sec. | |
| Sensor directivity angle ibeam anglej |
14‹ | |
| Power supply | Voltage | AC85`264V(15VA) |
| Power consumption | 15VA | |
| Display | LCD(with backlight) | |
| Output | Alarm output | 4 lines AC250V,DC30V 5A (Relay contact) |
imaximum load resistancej |
16bit RL(MAX)=600Ħ |
|
| Interface | RS-485 (Max.transmission rangeF1200‚j |
|
| Main unit | Sensor | |
| Operating ambient temperatures@@@ | |
|
| Material | ABS@ | PVC and other |
| Protection standard | IP66 | IP53 |
| Dimensions(W~D~H) | 185~85~235mm | ƒÓ264~181mm |
| Sensor cable length | - | 5‚ |
| Maximum sensor cable length | - | 200‚ |
| Distribution cable length | Not supplied | - |
| Weight | 1.8‚‹‚‡ | 1k‚‡ |
| Sensor attachment screwiold JISj | - | R1iPT1j |
Features
Ensures reliable measurements using the conical sensor.
¡Four alarm output lines are provided to enble various controls.
¡The RS-485 is provided as part of the standard configuration to enable remote control at a distance of up to 1,200 m.
The MODBUS protocol is provided as part of the standard configuration,enabling communications with a PLC.
¡The ultrasonic signals received are processed to reduce the effects of external noise and external ultrasonic waves.
¡Uses a conical sensor for compact dimensions and low weight.
Option
¡PROFIBUS communication converter
Individual Catalog
œIndividual catalog of HAL960 can be seen with PDF file.
(The information of HAL960 has not yet posted to Measuring Instruments General Catalog.)
HAL960 Individual CatalogiPDFF618kbj
![]() |
Install Adobe Reader to view the PDF file of this page. |