| Standard specification |
| Model No. | HD801 | HD802 | |
| Number of channels | 1CH | 2CH | |
| Frequency | 40‚‹Hz | ||
| Object to be measured | Liquid/powder | ||
| Measurement distance range (1/2 for powder) |
0.3 to 12m | ||
| Resolution | Measurement | 1mm | |
| Display | 1mm | ||
| Accuracy | }0.25%F.S. (}3cm) | ||
| Date update cycle | 1.3sec. | ||
| Sensor directivity angle ibeam anglej |
12‹ (Chemical resistanceF22‹) | ||
| Power supply | Voltage | AC85 to 264V | |
| Power consumption | 15VA | ||
| Display | LCD(with backlight) | ||
| Output | Alarm output | 4 lines for each channel AC250V,DC30V@5A (Relay contact) |
|
| 4-20mA current output imaximum load resistancej |
16bits for each channel RL(MAX)=600Ħ |
||
| Interface | RS-485 iMax.transmission rangeF1,200‚j |
||
| Main unit | Sensor | |
| Operating ambient temperatures@@@ | |
|
| Material | ABS@ | Standard: Epoxy and pp Chemically-resistant:PVDF |
| Protection standard | IP66 | |
| Dimensions(W~D~H) | 185~85~236.7mm | StandardFƒÓ84~60mm Chemically-resistantFƒÓ98~57mm |
| Sensor cable length | - | 5‚ |
| Maximum sensor cable length |
- | 200‚ |
| Distribution cable length | Not supplied | - |
| Weight | 1.8‚‡ | StandardF500g Chemically-resistantF860‚‡ |
| Sensor attachment screwiold JISj | - | StandardFR1iPT1j Chemically-resistantFG1iPF1j |
Features
¡Measures a wide range of distances:from 0.3 to 12m
¡Four alarm output line are provided to enable various controls for each channel.
¡The RS-485 is provided as part of the standard configuration to enable remote control at a distance of up to 1,200m.
@The MODBUS protocol is provided as part of the standard configuration,enabling communication with a PLC.
¡Provides a function to output differences in levels(channel1 - channel2).yHD802 onlyz
¡Standard and chemically-resistant sensors are available.
¡Weir flowmeter functionyHD801 onlyz
¡Up to eight alarm output linesyHD802 onlyz
Option
Applications and examples
¡Liquid/powder level management for a tank inside a machine
¡Water level measurement for lakes,ponda,or rivers
¡Application to large weir
Outline Drawing
œOutline Drawing in the electronic book style (P24).
HD801/HD802 Outline DrawingiPDFF192kbj
Individual catalog
œDetail information of HD801/HD802 in the electronic book style (P8).
Individual catalog of HD801(1CH)/HD802(2CH)iPDFF379kbj