MEASURING INSTRUMENT

HD801(1CH)/HD802(2CH)@ yUltrasonic Level Meterz

Ultrasonic Level Meter

Ultrasonic Level Meter@HD801/HD802

Standard specification

Model No. HD801 HD802
Number of channels 1CH 2CH
Frequency 40‚‹Hz
Object to be measured Liquid/powder
Measurement distance range
(1/2 for powder)
0.3 to 12m
Resolution Measurement 1mm
Display 1mm
Accuracy }0.25%F.S. (}3cm)
Date update cycle 1.3sec.
Sensor directivity angle
ibeam anglej
12‹
(Chemical resistanceF22‹)
Power supply Voltage AC85 to 264V
Power consumption 15VA
Display LCD(with backlight)
Output Alarm output 4 lines for each channel
AC250V,DC30V@5A
(Relay contact)
4-20mA current output
imaximum load resistancej
16bits for each channel
RL(MAX)=600Ħ
Interface RS-485
iMax.transmission rangeF1,200‚j


Main unit Sensor
Operating ambient temperatures@@@ -20 to 70Ž
Material ABS@ Standard:
Epoxy and pp

Chemically-resistant:PVDF
Protection standard IP66
Dimensions(W~D~H) 185~85~236.7mm StandardFƒÓ84~60mm

Chemically-resistantFƒÓ98~57mm
Sensor cable length - 5‚
Maximum sensor
cable length
- 200‚
Distribution cable length Not supplied -
Weight 1.8‚‡ StandardF500g

Chemically-resistantF860‚‡
Sensor attachment screwiold JISj - StandardFR1iPT1j

Chemically-resistantFG1iPF1j


Features
¡Measures a wide range of distances:from 0.3 to 12m
¡Four alarm output line are provided to enable various controls for each channel.
¡The RS-485 is provided as part of the standard configuration to enable remote control at a distance of up to 1,200m.
@The MODBUS protocol is provided as part of the standard configuration,enabling communication with a PLC.
¡Provides a function to output differences in levels(channel1 - channel2).yHD802 onlyz
¡Standard and chemically-resistant sensors are available.
¡Weir flowmeter functionyHD801 onlyz
¡Up to eight alarm output linesyHD802 onlyz



Option
¡PROFIBUScommunication converter



Applications and examples
¡Liquid/powder level management for a tank inside a machine
¡Water level measurement for lakes,ponda,or rivers
¡Application to large weir
HD800@Žg—p—á

Outline Drawing

œOutline Drawing in the electronic book style (P24).

HD801/HD802 Outline DrawingiPDFF192kbj



Individual catalog

œDetail information of HD801/HD802 in the electronic book style (P8).

Individual catalog of HD801(1CH)/HD802(2CH)iPDFF379kbj


get Adobe PDF Install Adobe Reader to view the PDF file of this page.
Measuring Instrument TEL:81-532-41-2177 MAIL:keisoku@honda-el.co.jp