| Reducing total costs with the two-wire system. |
![]() |
| Standard specification |
| Model No. | HAL420 | ||
| Number of channels | 1CH | ||
| Frequency | 50kHz | ||
| Object to be measured | Liquid | ||
| Measurement distance range | 0.3 to 6.5m | ||
| Resolution | Measurement | 1mm | |
| Display | 1mm | ||
| Accuracy | ±0.25%F.S. (±1.63cm) |
||
| Data update cycle | 1sec. | ||
| Sensor directivity angle (beam angle) |
14° | ||
| Power supply | Voltage | DC16〜32V | |
| Power consumption | 0.64W | ||
| Display | 4-digit LCD | ||
| Output | 4-20mAcurent output (maximum load resistance) |
12bit RL(MAX)=500Ω(24V) 2-wire system * |
|
| Main unit(sensor) | ||
| Operating ambient temperatures | ||
| Material | PP | |
| Protection standard | IP65(Without cap:IP20) | |
| Dimensions | φ93×110mm | |
| Distribution cable length | 10m | |
| Weight | 350g | |
| Sensor attachment screw(old JIS) | G2(PF2) | |
*【What is a two-wire system?】
A two-wire system is a signal transmission system in which
power for the amplifier drive is taken from the current
output signel,eliminating separate power supply wiring.
Features ■The sensor body is composed of chamically-resistant plastic(PP). ■Both display resolution and internal resolution are 1mm ■The sensor qand the control unit are integrated into a compact,lighweight unit.
Applications and examples
|